Performance and configuration
Analysis Range 0.01% to 99.99%
Accuracy 0.1%
Sample Form Solid, Powder, Liquid
Tube Voltage 5KV ~ 50KV
High Voltage Power Supply 0 ~ 50KV
Camera
HD Camera
Filters Selectable Customized Swtiches
Detector Type Proportional counter tube
Multichannel Analyzer Multi channel simulation
Sample Chamber Size 325*430*90(mm)
Test Time 5 ~ 60 secs
Measuring Element Au, Ag, Pt, Pd, Cu…
Analysis Software Qualitative & Quantitavtive Analysis Software
External Dimensions
430*430*350(mm)
Weight 33KG
Instruments Environmental Requirements
Ambient Temperature 5℃ ~ 38℃ (Suggested that in air conditioning room)
Relative Humidity 15% ~ 90%
Power Requirements AC220V ± 5V, 50/60Hz
EDS3900 EDS3900C
20230418/021530fa7e0dd1f73154321e10911b2f.jpg 20230418/e7cf4909c0e6a9dca8ce0745f4bfee80.jpg
Performance and configuration
Analysis Range 0.01% to 99.99%
Accuracy 0.1% 0.05%  To 0.1%
Sample Form Solid, Powder, Liquid
Tube Voltage 5KV ~ 50KV
High Voltage Power Supply 0 ~ 50KV
Light Control Current 0 mu A ~ 1000 mu A
Camera
HD Camera
Filters Selectable Customized Swtiches
Detector Type Proportional Counter tube
Multichannel Analyzer Multi channel simulation Digital multichannel
Sample Chamber Size 310*280*60(mm) 480*320*70(mm)
Test Time 5 ~ 60 secs
Measuring Element Au, Ag, Pt, Pd, Cu…
Analysis Software Qualitative & Quantitavtive Analysis Software
External Dimensions
400*430*350(mm) 500*340*230(mm)
Weight 33KG 20KG
Instruments Environmental Requirements
Ambient Temperature 5℃ ~ 40℃ (Suggested that in air conditioning room)
Relative Humidity 15% ~ 90%
Power Requirements AC220V ± 5V, 50/60Hz

No high power electromagnetic and vibration interference sources nearby

EDS7700 EDS7700T
20230418/74e5facb68a2d2f5c7a71aef1fa822cf.jpg 20230418/eb0c36e34dccc5a7c654a06c2c4f9506.jpg
Performance and configuration
Analysis Range 1 PPM to 99.99%
Accuracy 0.03%  (Au>96%) 0.01%  (Au>96%)
Sample Form Solid, Powder, Liquid
Tube Voltage 5KV ~ 50KV
High Voltage Power Supply 0 ~ 50KV
Light Control Current 0 mu A ~ 1000 mu A
Camera
HD Camera
Filters Selectable Customized Swtiches
Detector Type Si-pin (Amptek, USA) SDD (Amptek, USA)
Resolution 145 + 5 ev 135 + 5 ev
Multichannel Analyzer KEY -DMCP
Sample Chamber Size 380*380*60(mm)
Test Time 5 ~ 60 secs
Measuring Element 72 elements from sodium (Na) touranium (U) between all the elements
Analysis Software KEY-FP Qualitative & Quantitavtive Analysis Software
External Dimensions
480*480*390(mm)
Weight 38KG
Instruments Environmental Requirements
Ambient Temperature 5℃ ~ 40℃ (Suggested that in air conditioning room)
Relative Humidity 15% ~ 90%
Power Requirements AC220V ± 5V, 50/60Hz

No high power electromagnetic and vibration interference sources nearby

EDS8800 EDS8800T
3253b8ec85461d76f6675bcda47eba74.jpg
Performance and configuration
Analysis Range 1 PPM to 99.99%
Accuracy 0.03%  (Au>96%) 0.01%  (Au>96%)
Sample Form Solid, Powder, Liquid
Tube Voltage 5KV ~ 50KV
High Voltage Power Supply 0 ~ 50KV
Light Control Current 0 mu A ~ 1000 mu A
Camera
HD Camera
Filters Selectable Customized Swtiches
Detector Type Si-pin (Amptek, USA) SDD (Amptek, USA)
Resolution 145 + 5 ev 135 + 5 ev
Multichannel Analyzer Digital multichannel
Sample Chamber Size 310*270*80(mm)
Test Time 3 ~ 60 secs
Measuring Element 72 elements from sodium (Na) touranium (U) between all the elements
Analysis Software KEY-FP Qualitative & Quantitavtive Analysis Software
External Dimensions
460*390*360(mm)
Weight 38KG
Instruments Environmental Requirements
Ambient Temperature 5℃ ~ 40℃ (Suggested that in air conditioning room)
Relative Humidity 15% ~ 90%
Power Requirements AC220V ± 5V, 50/60Hz

No high power electromagnetic and vibration interference sources nearby

EDS9800 EDS9800T
20230418/220004ba0ae4c3b5cd5e5bfccd6c7cde.jpg
Performance and configuration
Analysis Range 1 PPM to 99.99%
Accuracy 0.03%  (Au>96%) 0.01%  (Au>96%)
Sample Form Solid, Powder, Liquid
Tube Voltage 5KV ~ 50KV
High Voltage Power Supply 0 ~ 50KV
Light Control Current 0 mu A ~ 1000 mu A
Camera
HD Camera
Filters Selectable Customized Swtiches
Detector Type Si-pin (Amptek, USA) SDD (Amptek, USA)
Resolution 145 + 5 ev 135 + 5 ev
Multichannel Analyzer Digital multichannel
Sample Chamber Size 310*270*90(mm)
Test Time 3 ~ 60 secs
Measuring Element 72 elements from sodium (Na) touranium (U) between all the elements
Analysis Software KEY-FP Qualitative & Quantitavtive Analysis Software
External Dimensions
480*440*368(mm)
Weight 36KG
Instruments Environmental Requirements
Ambient Temperature 5℃ ~ 40℃ (Suggested that in air conditioning room)
Relative Humidity 15% ~ 90%
Power Requirements AC 220V ± 10V, or AC 110V ± 10V, 50/ 60 Hz